Step | | Procedure & Parts & Tools |
1 |
|
REMOVE THE 3 SCREWS HOLDING THE HANDLE COVER.
Screwdriver-phillips |
|
|
2 |
|
REMOVE HANDLE COVER.
|
3 |
|
PULL THE 2 WIRE CONNECTORS TO REMOVE WIRES FROM MICROSWITCH.
|
4 |
|
INSERT THE 2 LEADS INTO THE WIRE CONNECTORS. TURN THE KEY ON AND PULL THE HANDLE BAIL FORWARD TO ACTIVATE MACHINE. SET THE VOLT METER TO VOLTAGE. VOLT METER SHOULD READ APPROX. 24 VOLTS.
Volt meter (True RMS capable) |
|
|
|